2013年9月20日星期五

Best Motorola Solutions MSC-241 test training guide

ITCertKing provide different training tools and resources to prepare for the Motorola Solutions MSC-241 exam. The preparation guide includes courses, practice test, test engine and part free PDF download.

In today's competitive IT industry, passing Motorola Solutions certification MSC-241 exam has a lot of benefits. Gaining Motorola Solutions MSC-241 certification can increase your salary. People who have got Motorola Solutions MSC-241 certification often have much higher salary than counterparts who don't have the certificate. But Motorola Solutions certification MSC-241 exam is not very easy, so ITCertKing is a website that can help you grow your salary.

ITCertKing is a very good website for Motorola Solutions certification MSC-241 exams to provide convenience. According to the research of the past exam exercises and answers, ITCertKing can effectively capture the content of Motorola Solutions certification MSC-241 exam. ITCertKing's Motorola Solutions MSC-241 exam exercises have a very close similarity with real examination exercises.

Exam Code: MSC-241
Exam Name: Motorola Solutions (Design and Deploy for MOTOTRBO Solutions EMEA)
One year free update, No help, Full refund!
Total Q&A: 108 Questions and Answers
Last Update: 2013-09-20

Are you struggling to prepare Motorola Solutions certification MSC-241 exam? Do you want to achieve the goal of passing Motorola Solutions certification MSC-241 exam as soon as possible? You can choose the training materials provided by ITCertKing. If you choose ITCertKing, passing Motorola Solutions certification MSC-241 exam is no longer a dream.

If you use the ITCertKing Motorola Solutions MSC-241 study materials, you can reduce the time and economic costs of the exam. It can help you to pass the exam successfully. Before you decide to buy our Motorola Solutions MSC-241 exam materials, you can download our free test questions, including the PDF version and the software version. If you need software versions please do not hesitate to obtain a copy from our customer service staff.

MSC-241 Free Demo Download: http://www.itcertking.com/MSC-241_exam.html

NO.1 A Capacity Plus system consists of three (3) repeaters with repeater one (1) the master and
repeaters two (2) and three (3) as peers. On the 24th of May, there is a lighting strike at the site
and the building lost power, causing the three repeaters to revert to DC power. The design of the
site called for just the repeaters to be battery backed. However the next morning the customer
calls and reports that a number of talkgroups are getting busy tones (engaged), yet other groups
are seeing no busy tones (engaged) on the system. Which of the following statements BEST
describe the issue?
A. The master has gone down and taken the rest of the Capacity Plus network with it.
B. The peers use DHCP and were not able to connect to the master and refresh their peer list and
went off the Capacity Plus network as their leases expired.
C. The switch was not on battery backup and there are no LAN connections on the Capacity Plus
system, each of the repeaters are now operating as three (3) independent Capacity Plus systems.
D. The peers use DHCP and were not able to connect to the master and refresh their peer list.
The dealer should have used static IP addresses throughout.
Answer: C

Motorola Solutions dumps   MSC-241 original questions   MSC-241   MSC-241   MSC-241

NO.2 Which of the following are TRUE statements about operating a MOTOTRBO repeater in an IP
Site
Connect configuration?
A. One of its logical channels can work in IP Site Connect mode (over wide area) and the other
logical channel can work in digital repeater mode (single site over local area).
B. Both logical channels can work in digital repeater mode (single site over local area).
C. Both logical channels can work in IP Site Connect mode (over wide area).
D. Only A and B are true (C is false).
E. Only A and C are true (B is false).
F. A, B, and C are true.
Answer: F

Motorola Solutions study guide   MSC-241   MSC-241   MSC-241 exam

NO.3 Which of the following antennas is BEST suited for providing coverage inside a tall building?
A. 4 element Yagi
B. Radiating coaxial cable
C. End-fed half-wave antenna
D. High gain collinear antenna
Answer: B

Motorola Solutions   MSC-241   MSC-241   MSC-241 certification training   MSC-241 demo   MSC-241

NO.4 What will Enhanced Channel Access improve?
A. The amount of GPS updates that can be sent on a data revert channel
B. The amount of time from when PTT is pressed until voice is sent
C. Call success rate
D. Call setup time
Answer: C

Motorola Solutions   MSC-241 pdf   MSC-241 exam prep   MSC-241

NO.5 On which type of channel in an IP Site Connect system are Transmit Interrupt features
supported
in repeater firmware releases R01.08.00 and higher?
A. Wide Area Slots only
B. Local Area Slots only
C. Both Wide and Local Area slots
D. Noneoftheabove
Answer: D

Motorola Solutions   MSC-241   MSC-241

NO.6 A MOTOTRBO repeater is connected to a Zetron Model 35 Telephone Interconnect. If a
telephone
user dials the Telephone Interconnect number, they get a busy signal (engaged tone). If a radio
user dials any telephone number, they don’t hear the ringing tone, only silence. Upon visiting the
site, you find that when a radio user dials, the relay click can be heard from the Zetron Model 35.
Unplugging the RJ11 and dialing the Telephone Interconnect, still results in a busy signal
(engaged tone). With this information, what do you think could be wrong?
A. The Zetron Model 35 may be faulty.
B. The Zetron Model 35 has probably not been configured for the phone line Ringer Equivalence
Number (REN).
C. The RJ11 cable may have a short circuit or there is a short circuit somewhere between the site
and the exchange.
D. The repeater interface cable to the Zetron Model 35 is faulty.
Answer: C

Motorola Solutions   MSC-241   MSC-241 pdf   MSC-241 exam

NO.7 Which of the following are TRUE statements about operating a MOTOTRBO repeater in a
Capacity Plus configuration?
A. One of its logical channels can work in trunked mode and the other logical channel can work in
data revert mode.
B. Both logical channels can work in trunked mode.
C. Both logical channels can work in data revert mode.
D. Only A & B are true (C is false)
E. Only B & C are true (A is false)
F. A, B, & C are true
Answer: F

Motorola Solutions certification training   MSC-241   MSC-241   MSC-241

NO.8 A Capacity Plus system consists of three (3) repeaters with repeater one (1) the master and
repeaters two (2) and three (3) as peers. The dealer needs to make a simple change in repeater
two (2) and utilize IP repeater programming (IRP) to access the repeater remotely. A couple of
days later the customer calls and complains about users getting system busy tones (engaged
tones).
The dealer attempts to connect an RDAC remotely to the system with no success. He has verified
he can communicate to the router at the site.
Which of the following statements BEST describes the issue?
A. The master has gone down and taken the rest of the Capacity Plus network with it.
B. The master has gone down and the system is operating on just two (2) repeaters.
C. There is RF interference on the channel and the master repeater is unable to communicate to
the peers.
D. The peers are using DHCP and are not able to connect to the master and refresh their peer list.
The system is operating on just the master.
Answer: B

Motorola Solutions   MSC-241   MSC-241   MSC-241 pdf

NO.9 You are looking to optimize battery life of radios that are close to the base station. Which is
the
most likely parameter for optimizing the battery life of a radio for a Capacity Plus system?
A. Beacon interval
B. Beacon duration
C. High power mode in Radio
D. Low power mode in Radio
Answer: D

Motorola Solutions test questions   MSC-241   MSC-241   MSC-241 test questions   MSC-241

NO.10 What changes are required to the Master Repeater in an IP Site Connect system when a new
peer
is added to the system?
A. Both the IP address and port number of the new repeater must be configured into the Master
Repeater.
B. The address of the new peer must be configured into the Master Repeater.
C. The port of the new peer must be configured into the Master Repeater.
D. No changes are required to the Master Repeater.
Answer: D

Motorola Solutions practice test   MSC-241 exam dumps   MSC-241   MSC-241   MSC-241   MSC-241

ITCertKing offer the latest LOT-951 exam material and high-quality HP0-S33 pdf questions & answers. Our 000-656 VCE testing engine and CAT-380 study guide can help you pass the real exam. High-quality 1Z0-478 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.